Select the region/language

Product center

PRODUCT CENTER

home page> Product center > Intelligent industry > Gridded air quality monitoring
MORE+
< >

Gridded air quality monitoring micro-station

At present the characteristic of the air pollution in our country has changed from coal-smoke type pollution to compound pollution. According to the materials released by the Ministry of Environmental Protection, there has been no fundamental change in China's coal-based energy structure, coal-smoke pollution has been the main type of pollution for a long time, and the problem of sulfur dioxide inhalable particulate matter pollution in urban atmosphere has not been solved. At the same time, the number of motor vehicles continues to increase, exhaust pollution is becoming more serious, gray haze, photochemical smog, acid rain and other complex air pollutants are increasingly prominent. Among them, ozone, inhalable particulate matter, sulfur dioxide, nitrogen oxides, and volatile organic compounds are the main pollutants in the atmosphere. Studies have shown that photochemical smog, high concentrations of ozone, nitrogen oxide pollution and so on gradually appear in the Beijing-Tianjin-Hebei, Pearl River Delta and Yangtze River Delta.

National hotline

400-992-0476

Immediate consultation
last:
...have been exhausted
next:
RA600-ZS noise on-line monitoring system
  • product details
  • Product customization and matching

 产品特点:

高度集成:可同时集成颗粒物、SO2、CO、NO2、O3、TVOC、气象五参数等传感器;

光学切割: 颗粒物光学粒径切割,可同时监测PM1.0、PM2.5、PM10、TSP

恒流控制: 增加流量反馈、实现恒流控制、保证采样量稳定性、提高精确度

内置保护: 具有鞘气保护功能、具有气路保护功能

专业设计: 设计院专业设计结构,便于安装

分级气路: 颗粒物主气路、气体模块辅气路,双泵吸气路功能;

数据稳定: 具备温湿度感应、气体交叉干扰算法,零点漂移及跨度量程校准;

动态除湿: 可配备动态加热除湿采样系统,避免潮湿环境对数据的影响

数据传输: 4G,RS232/RS485

数据导出:具有USB口/或SD卡,支持本地导出功能(具有本地存储及导出功能,本地存储容量>530000条)

环境普适: 防雨防雪防雷;

设备溯源: 可溯源至NIST

续传功能: 具有断电保护、断网续(补)传功能;

信息质控: 有设备信息管理、数据管理和数据质控功能

显示方式: 具备本地LCD显示与调试功能

多重过滤: 具备两级及以上过滤系统,避免样气中异物影响气体传感器的准确性和精度;

使用寿命主机10年以上,颗粒物传感器5年以上,气体传感器2年以上;

校准/校零: 具备自动/手动校零、校准功能

 技术参数:

颗粒物测量方法:

激光散射法

颗粒物测量参数:

PM2.5 、PM10PM100、TSP

颗粒物测量浓度范围:

0-30(mg/m³)

颗粒物浓度测量精度:

0.1(μg/m³)

颗粒物浓度测量准确度:

±10%

无机气体测量方法:

电化学法

无机气体测量参数:

SO2、NO2、CO、O3TVOC

无机气体测量浓度范围:

SO2:0-1PPM

NO2:0-1 PPM

CO:0-200 PPM

O3:0-5PPM

TVOC:0-20PPM

无机气体测量浓度精度:

SO2:0.001PPM

NO2:0.001PPM

CO:0.01PPM

O3:0.001PPM

TVOC:0.001PPM

无机气体测量准确度

S02:±5%

NO2:±5%

CO:±5%

O3:±5%

TVOC±5%

气象参数:

温度:-50 ~ 100℃;±0.3℃

湿度: 0 ~ 100RH;±3% RH

风速: 0~30m/s;±1m/s

风向: 0~360°;±3°

气压: 1~120kPa;±0.15kPa

数据传输:

4G传输,可上传数据平台,标准HJ212-2017通讯协议

防水等级:

IP53

    :

AC 220V

接口输出:

RS232、485等

安装方式:

立杆/支架安装



Master the core customization selection

related products
Scan wechat